Device driver interfaces

This document describes all known functions for all known device drivers. It does not include file IO, even when done through the same interfaces.

The device drivers documented are:

ID Description
SND: Sound device
TIM: Timer device
ALM: Alarm device
WLD: World device
TTY: Serial port device (including IR)
PAR: Parallel port device
FRC: Free running counter
XMD: XModem driver
YMD: YModem driver
WLS: Workabout laser scanner
AIR: AccessIr driver
N/A Console device

Types of device driver

On the Series 3, much functionality, including the filing system, is provided via device drivers. There are three kinds of device drivers:

  • physical device drivers: these drive the hardware directly
  • base logical device drivers: these provide a basic abstraction for working with logical device drivers
  • stacked logical device drivers: these provide higher levels of abstraction

Only logical device drivers need to know about physical device drivers; all user applications operate through logical device drivers.

For example, the 3-Link pod and cable might be accessed through a physical device driver called TTY.LNK: (all physical device drivers have a two part name). This is automatically loaded the first time that the logical device driver TTY: is opened, and TTY: will use it to actually communicate with the pod.

When TTY: is opened, the kernel will return a handle. Read and write operations on that handle will send data directly to and from the port. Alternatively, the XMD: device driver could be stacked on top of TTY: on that handle. Once this has been done, read and write on that handle will now be done via the XMD: driver, which wraps the data in the XModem protocol and calls the TTY: driver to do the actual output. There is no limit to how many device drivers can be stacked upon one another.

Opening a handle

A base logical device driver is opened with the IOOPEN keyword or the IoOpen system call; a stacked logical device driver is opened with IoOpen. The name is examined to see whether it has a colon as the fourth character but not the fifth; if so, it is split into a device name and a channel name. The kernel then checks that the logical device exists; if not, or if the name does not have the correct form, it prefixes FIL: to the name and tries again (FIL is the filing system logical device driver). For example:

Example Device Channel Name
SND: SND Blank
TTY:A TTY A
FIL:A:XXX FIL A:XXX
HELLO.TXT FIL HELLO.TXT
ROM::XXX FIL ROM::XXX
FIL:TTY: FIL TTY:
QXV: FIL QXV:

The last example assumes there is no QXV device driver

The filing system and the FIL: driver are described in the Psionics file FILEIO. All other known drivers are described here.

IOOPEN and IoOpen are passed a mode to open the device or file. Drivers other than the filing system and those specifically mentioning it ignore the mode. It is recommended that a mode of -1 be used, as this is always rejected by the
filing system; thus an error in the device name or a missing driver will be detected. Note that the IOOPEN keyword uses a qstr, while the IoOpen system call uses a cstr.

A driver may refuse to open a given channel name, or all channels, more than a certain number of times without closing some first. For example, a TTY driver might only allow one open handle at a time for each port.

In OPL there are two special handles that do not need to be opened:

  • -1: the device opened by LOPEN
  • -2: the console device (see below)

Using the device driver

Once a device driver has been opened, it is accessed with the keywords IOW, IOA, and IOC (Series 3a only). These keywords offer the same services, and differ only in the way completion is indicated.

  • IOW waits until the operation completes, and then returns. No signal is generated.
  • IOA has an extra status variable argument. The variable is set to -46 at the start of the operation, and then to the final result when it completes; a signal is generated at this moment (it can be collected with IOWAIT or IOWAITSTAT). Note that some operations complete immediately, and so the status of -46 is never seen.
  • IOC is like IOA, but if the operation completes immediately, it places the result into the status variable and generates a signal. Thus the code making the call can check the result in one place (after collecting the signal) rather than two (after the call and after the signal).

Each call is passed a function number and two parameters for passing other information. The latter identify blocks of memory; the actual argument can be either the name of an OPL variable (typically the first element of an array),
in which case that variable marks the start of the block, or it can be the # operator applied to the address of the block. The former is equivalent to #ADDR(variable).

If the parameter is shown as "unused", then any variable or value can be used, as it will be ignored; it is often convenient to use #0 as such an argument.

Unless stated otherwise, a successful call returns zero, and an unsuccessful call some non-zero error code.

Standard functions

These functions apply to all drivers.

Function 1 (read) and Function 2 (write)

  • Argument 1: buffer
  • Argument 2: count (word)

These functions are equivalent to the IOREAD and IOWRITE keywords. They read or write up to the specified number of bytes from or to the device; in the case of function 1, the count is changed to the actual amount read.

These functions can be used with any handle that is using a driver labelled as a data device (such as the serial port device or the XModem driver).

Function 3

  • Argument 1: unused
  • Argument 2: unused

This will close the handle; it is equivalent to the IOCLOSE keyword.

Function 4

  • Argument 1: unused
  • Argument 2: unused

This will cancel any uncompleted function on the handle; the function will complete immediately, with the status variable set to -48 ("I/O cancelled"). A signal will still be generated, and must be collected with IOWAITSTAT or IOWAIT.

Sound device (SND:)

The sound device has the name SND:. There are no channel names. Only one handle can be open at a time, and so the device should be closed as soon as possible.

Function 1 (sound channel 1) and Function 2 (sound channel 2)

  • Argument 1: note information
  • Argument 2: word holding number of notes

This function is supported by the HC, MC, and Series 3a only.

This plays a sequence of notes on the specified sound channel. The note information is an array of words, two per note; the first is the frequency of the note (in Hz), and the second the duration in beats (see function 7). The sound will not start until both these functions have been called (thus ensuring the sound is synchronised on both channels). The function completes when the specified channel finishes playing, even if the other has not.

Function 7

  • Argument 1: 2 byte information block
  • Argument 2: unused

The characteristics of the sound system are set according to the block:

  • Offset 0 (byte): beats per minute (2 to 240, default 120)
  • Offset 1 (byte): volume (0 max to 5 min)

The beats per minute is only supported by the HC, MC, and Series 3a. On the Series 3a, volumes 1 and 2 are identical, as are 4 and 5. On the Series 3t, volumes 0 and 5 are unavailable.

Function 8

  • Argument 1: 2 byte information block
  • Argument 2: unused

The block is filled in with information about the sound channel, using the same format as function 7.

Function 9

  • Argument 1: alarm type (0 = rings, 1 = chimes)
  • Argument 2: unused

The specified alarm is played; this function completes when the sound has completely played.

Function 10

  • Argument 1: phone number (cstr)
  • Argument 2: parameter block

This generates DTMF dialling sounds. The number contains the digits to be dialled (0 to 9, *, #, and A to F can be used; E is the same as *, and F the same as #). The parameter block has the format:

  • Offset 0 (byte): tone length )
  • Offset 1 (byte): delay length ) all in 1/32 seconds
  • Offset 2 (word): pause length )

Timer device (TIM:)

The timer device has the name TIM:. There are no channel names.

Several channels may be opened at the same time by the same process.

Function 1

  • Argument 1: delay in 1/10 seconds (long)
  • Argument 2: unused

This will complete after the specified delay. Time when the machine is switched off is not counted as part of the delay. Changing the system clock will not affect the completion of this function.

Function 2

  • Argument 1: abstime (long)
  • Argument 2: unused

This will complete at the specified time. If the machine is switched off at that time, it will switch back on. Changing the system clock will affect the completion of this function.

Alarm device (ALM:)

The alarm device has the name ALM:. There are no channel names.

Function 1 (display date only) and Function 2 (display date and time)

  • Argument 1: time specification block
  • Argument 2: message (cstr)

This schedules an alarm, which causes a message box to be shown at some later time. The time specification block has the format:

  • Offset 0 (long): abstime when the alarm should sound
  • Offset 4 (long): abstime to be displayed in the message box

The message (maximum 64 characters) is shown in the message box.

The function completes when the alarm goes off. If the machine is switched off at that time, it will switch back on. Changing the system clock will affect the completion of this function.

Function 10 (display date only) and Function 11 (display date and time)

  • Argument 1: time specification block
  • Argument 2: message (cstr)

These functions are supported by the Series 3a only.

This schedules an alarm, which causes a message box to be shown at some later time. The time specification block has the format:

Offset Length Description
0 4 abstime when the alarm should sound
4 4 abstime to be displayed in the message box
8 qstr name of alarm sound

These functions are identical to functions 1 and 2, except that the alarm sound is specified by the call. The sound name may be one of the following:

  • the name of a sound file; this is searched for in each of (This appears to be the search order, but it is not documented.)
    • A:\WVE\name.WVE
    • B:\WVE\name.WVE
    • M:\WVE\name.WVE
    • ROM::name.WVE
  • The Series 3a ROM contains the sounds:
    • SYS$AL01 Fanfare
    • SYS$AL02 Soft bells
    • SYS$AL03 Church bell
  • a single byte (thus offset 8 is set to 1) with the value 1 (for rings), 2 (for chimes), or 16 (for silence).

World device (WLD:)

The world device has the name WLD:. There are no channel names.

This device gives access to the World database. This includes the built-in database and any one world file. If the World application is running, this is the file it currently has open. Otherwise it is the last world file to be open,
or the world file opened with function 21.

World files have a format which varies from version to version of the operating system, and are limited to 32 entries. This is because the file is mapped into kernel address space and accessed directly, rather than being loaded in the usual manner.

Several functions use a "city name block". This is a 42 byte block with the format:

Offset Length Description
0 21

name of a city (cstr)

21 21

name of a country (cstr)

Unless stated otherwise, the country is that in which the city lies.

Many functions establish or use a searching order. This can be set to:

  • all cities, in alphabetical order ("city order")
  • capital cities, in alphabetical order of country ("country order")

Search order is cyclic: The last city or country is followed by the first.

Function 10

  • Argument 1: clue (cstr)
  • Argument 2: city name block

This locates a city whose name begins with the clue (the search is done with folded strings, so "lon" will find London, but "ond" will not). If successful, the city block is filled in with the city, and city order is set.

Function 11

  • Argument 1: clue (cstr)
  • Argument 2: city name block

This locates a country whose name begins with the clue (the search is done with folded strings, so "lon" will find London, but "ond" will not). If successful, the city block is filled in with the capital city of the country, and country order is set.

Function 12

  • Argument 1: city name block
  • Argument 2: unused

This locates either the city whose name is in the city part of the block, or, if the city part is an empty string, the capital city of the country whose name is in the country part of the block (in either case, the string must be exact after folding). If successful, the block is filled in, and city or country order (according to what was searched for) is set.

Function 13 (next city) and Function 14 (previous city)

  • Argument 1: city name block
  • Argument 2: unused

These functions fill the block with the next (or previous) city in the current search order.

Function 15

  • Argument 1: city name block
  • Argument 2: unused

This function fills the block with the home city; city order is set.

Function 16

  • Argument 1: unused
  • Argument 2: unused

This function sets the home city to the last city returned.

Function 17

  • Argument 1: city name block
  • Argument 2: unused

This function fills the block with the capital city of the default country; city order is set.

Function 18

  • Argument 1: unused
  • Argument 2: unused

This function sets the default country to that of the last city returned.

Function 19

  • Argument 1: original number (cstr)
  • Argument 2: diallable number (cstr)

This function generates a diallable number (up to 24 characters) from the original number (up to 128 characters), using the following rules:

  • all characters before the first digit are stripped from the number;
  • the number then ends at the first character other than a digit, space, or the special characters * # , and - (star, hash, comma, and dash);
  • if there are any spaces or dashes in the number, they are removed and the diallable number is modified as follows:
    • if the first digit was a zero, it is removed;
    • if the home city is not in the default country, the sequence is prefixed with the international sequence to dial from the home city to the default country;
  • if not, the number is precisely those characters left.

For example, abc,123,456xx789 generates "123,456". Assuming that the default country is the UK and the default city is in the USA, abc00-34 56x78 generates "01144003456".

David said that this just generates the dial string

David implied this also does [country]

Function 20

Argument 1 = 0 or 1

  • Argument 1: (word) the value 0 (to add) or 1 (to update)
  • Argument 2: 80 byte information block

Adds or updates the city described by the information block (in the format of function 22) to the open world file.

Argument 1 = 2

  • Argument 1: (word) the value 2
  • Argument 2: unused

The current item is deleted from the open world file if it is in it, not the current home city, and not a capital city of an added country. The function returns 1 if the entry was hiding an entry in the ROM database, and 0
otherwise.

Argument 1 = 3

  • Argument 1: (word) the value 3
  • Argument 2: 66 byte information block

Adds or updates the country described by the information block (in the format of function 23) to the open world file. All cities in the country will have their GMT offset and DST rule updated to match the data.

Function 21

  • Argument 1: (word) mode (0 = open, 1 = create, 2 = replace)
  • Argument 2: (cstr) filename

This function opens, creates, or replaces a world file for use. The modes have the meanings described in the Psionics file FILEIO. If the last returned city is in the database, it is no longer valid (but functions 13, 14, and 25 still
work). The default extension is .WLD.

Function 22

  • Argument 1: 80 byte buffer
  • Argument 2: unused

This function fills the buffer with information about the last city returned:

Offset Length Description
0 21 (cstr) city name
21 21

(cstr) country name

43 1 DST rule: 0 = none, 2 = European, 4 = North, 8 = South
44 2 minutes ahead of GMT for city
46 2 city latitude in minutes north (negative means south)
48 2 city longitude in minutes west (negative means east)
50 17 (cstr) dial code from home city
67 9 (cstr) area code of city
76 2 X coordinate of city on map (in pixels)
78 2 Y coordinate of city on map (in pixels)

Function 23

  • Argument 1: 66 byte buffer
  • Argument 2: unused

This function fills the buffer with information about the country of the last city returned:

Offset Length Description
0 21 (cstr) city name
21 21 (cstr) country name
43 1 DST rule: 0 = none, 2 = European, 4 = North, 8 = South
44 2 minutes ahead of GMT for capital city
46 5 (cstr) national dialling code
51 5 (cstr) international dialling code
56 5 (cstr) country code

Function 24

  • Argument 1: (word) status
  • Argument 2: 66 byte information block

This function does a calculation on the contents of the information block. The function should be called with the status set to 1. If it returns successfully, then, as long as the status is non-zero, it should be called again. When the
status is zero, the calculation has completed. Intermediate stages may use extra internal memory, so if you wish to abandon the calculation partway, use function 4 to cancel (this can be done at any time) rather than just stopping.

The initial value of the information block should be:

Offset Length Description
42 1 units (0 = miles, 1 = km, 2 = nautical miles)
43 1 DST rule: 0 = none, 2 = European, 4 = North, 8 = South
44 2 minutes ahead of GMT for city
46 2 point latitude in minutes north (negative means south)
48 2 point longitude in minutes west (negative means east)

The final value of the information block is:

Offset Length Description
0 2 distance in stated units from home city to point
2 2 sunrise time at point in minutes past midnight
4 2 sunset time at point in minutes past midnight
6 2 0 = times valid, 1 = light all day, -1 = dark all day

Function 25

  • Argument 1: city name block
  • Argument 2: unused

This function returns the next city in the same country as the last city returned (using city order).

Serial port device (data device) (TTY:)

The serial port device has the name TTY:. The channel name is a single letter from A to Z, identifying the particular port to use. Which ports are actually provided depends on the specific system.

On the Series 3t and 3a, the two RS-232 ports are channels A and B. On those machines with an infra-red port, it is channel I.

An open serial port can be read and written with IOREAD and IOWRITE, or with IOW functions 1 and 2.

Function 7

  • Argument 1: 12 byte control block
  • Argument 2: unused

This function sets various characteristics of the serial port. The control block has the format:

Offset Length Description
0 1 transmit baud rate
1 1 receive baud rate
2 1 Framing
3 1 0 = no parity, 1 = even parity, 2 = odd parity
4 1 handshaking
5 1 XON character (usually 17)
6 1 XOFF character (usually 19)
7 1 Flags
8 4 terminating mask

The terminating mask specifies which of the characters with codes 0 to 31 terminate a read. For example, if bits 10 and 13 are set, then a read on the port will terminate after reading a byte with value 10 or 13.

Baud Rates (Offset 0 and 1)
ID Baud rate (bps)
1 50
2 75
3 110
4 134
5 150
6 300
7 600
8 1200
9 1800
10 2000
11 2400
12 3600
13 4800
14 7200
15 9600
16 19200
17 38400
18 57600
19 115200
Framing (Offset 2)
Bit(s) Description
0-3 number of data bits minus 5 (e.g. 3 means 8 bits)
4 0 = 1 stop bit, 1 = 2 stop bits
5 parity bit enabled if set
Handshaking (Offset 4)
Bit(s) Description
0-1 3 = XON handshaking, 0 = no XON handshaking
2 0 = RTS handshaking, 1 = no RTS handshaking @@@@
3 1 = DSR handshaking, 0 = no DSR handshaking

(Any combination of XON, RTS, and DSR can be set at once.)

Flags
Bit Offset 0: Speed Supported (baud)
0 Ignore parity errors

Function 8

  • Argument 1: 12 byte control block
  • Argument 2: unused

This function fills the control block with the current settings (see function 7).

Function 9

  • Argument 1: unused
  • Argument 2: unused

This function discards any buffered input and any error state. Any handshaking is set to restart reception.

Function 10

  • Argument 1: count (word)
  • Argument 2: unused

The count is set to the number of bytes buffered and waiting to be read.

Function 11

  • Argument 1: 2 byte control block
  • Argument 2: unused

The first byte of the control block is set to indicate the state of the modem control lines:

Value Description
0 set if CTS active
1 set if DSR active
2 set if DCD active

The second byte specifies the new setting for the DTR line:

Value Description
0 leave unchanged
1 set DTR active
2 set DTR inactive

Function 12

  • Argument 1: 6 byte information block
  • Argument 2: unused

The information block is filled in to indicate which facilities are supported by the port.

Offset Length Description
0 4 Speed Supported (baud)
1 2 Feature Supported
Speed Supported in baud (Offset 0)
Bit Offset 0: Speed Supported (baud)
0 50
1 75
2 110
3

134

4 150
5 300
6 600
7 1200
8 1800
9 2000
10 2400
11 3600
12 4800
13 7200
14 9600
15 19200
16 38400
17 57600
18 115200
Offset 4: Feature Supported
Bit Offset 4: Features Supported
0 supports 5 bits
1 supports 6 bits
2 supports 7 bits
3

supports 8 bits

4 supports 2 stop bits
5 supports even parity
6 supports odd parity
7 supports mark parity
8 supports space parity
9 supports setting DTR
10 supports different transmit and receive baud rates
11 supports soft XON/XOFF characters

Parallel port device (data device) (PAR:)

The parallel port device has the name PAR:. The channel name is a single letter from A to Z, identifying the particular port to use. Which ports are actually provided depends on the specific system. A port will consume power while open.

An open parallel port can be written with IOWRITE, or with IOW function 2.

No other functions are available on the Series 3.

Free running counter (FRC:)

The Free running counter has the name FRC:. There are no channel names. It is only available on the Series 3a. Only one process may have the FRC open at a time, and so it should be closed as soon as possible.

In the following description, an "FRC-tick" is 1/1024 seconds.

Function 1

  • Argument 1: (word) set to current count
  • Argument 2: unused

The current setting of the counter is placed in the word. If the counter is in mode 1, the count is then reset to zero (the counter continues counting). This call will not complete while the counter is zero.

Function 15

  • Argument 1: (word) operating mode (0 or 1)
  • Argument 2: (word) step time (10 to 65535)

Starts the counter from zero. Mode 0 means that the counter will increment every FRC-tick. Mode 1 means that the counter will increment at every N FRC-ticks, where N is the step time. Any uncompleted function on the counter will be completed.

XModem and YModem drivers (data device) (XMD: and YMD:)

The XModem driver has the name XMD: and the YModem driver the name YMD:. There are no channel names. Both are stacked on to another data device.

Once stacked, the driver will use the underlying device to transfer data using the XModem (single transfer) or YModem (multiple transfer) protocol. These protocols have a number of variants:

  • XModem may use checksums or CRCs on each frame. CRCs are more reliable.
  • YModem may use the error correcting or G mode. The G mode does not allow errors to be corrected, only detected.
  • The transfer may use short frames (128 data bytes) only, or both short and long frames (1024 data bytes).

Function 1 is used to receive data. The initial value of the length argument will be ignored, and a whole frame (128 or 1024) bytes will be placed in the buffer, which must therefore be large enough. When an end-of-file message is received, the function will fail with error -36.

Function 2

Function 2 is used to send data. The length is used as follows:

  • 0 : an end-of-file message is sent
  • 128: a short frame is sent
  • 1024: a long frame is sent

If the length is any other value, the specified amount of data is transferred, followed by enough 0x1A bytes to fill a frame (a short frame if the length is less than 128, and a long frame otherwise).

With YModem, the first frame must be a short frame with the following contents, in order:

  • (cstr) file name
  • file length in bytes (decimal digits)
  • a single space, then the abstime file last modified (octal digits)
  • a single space, then the file mode, using Unix conventions (octal digits)
  • a single space, then the sending software version number (octal digits)

The last field or fields may be omitted, provided that the name is present. The rest of the frame must contain only zero bytes. A frame consisting only of 128 zero bytes indicates that there are no more files.

Function 10

  • Argument 1: (word) direction: 0 = transmit, 1 = receive
  • Argument 2: (word) mode

This establishes a connection with the other end of the link. The direction indicates which way the file transfer will take place. The mode is one of the following values:

If long frames are to be rejected while receiving:

XModem:

  • 0 = CRC mode if supported by far end, otherwise checksum mode
  • 1 = CRC mode
  • 2 = Checksum mode

YModem:

  • 3 = Error correcting mode
  • 4 = G mode

If long frames are to be accepted while receiving:

XModem:

  • 0x8001 = CRC mode

YModem:

  • 0x8003 = Error correcting mode
  • 0x8004 = G mode

With YModem, this function must be called for each file.

Function 11

  • Argument 1: unused
  • Argument 2: unused

This disconnects an existing connection while leaving the driver attached. With YModem, this function should not be called between files.

Workabout laser scanner (WLS:D)

The laser scanner has the device name WLS: and channel name D (that is, it is opened as WLS:D). Only one handle can be open at a time. Furthermore, opening the device activates the scanner for 5 seconds, after which it will no longer read and should be closed; it should also be closed after a successful read.

Reading from the device returns a string which is not terminated (the amount of data read gives the length). There are no other IO functions known.

AccessIR device (data device) (AIR:)

The AccessIR device has the name AIR:. There are no channel names. Only one handle can be open at a time, and so the device should be closed as soon as possible.

On the Series 3c, the device is built-in to the kernel and is always available. On the Siena it is provided as a separate file called ACCESSIR.LDD, and is only available once it has been loaded with system call DevLoadLDD.

There is a separate IR protocol stack process. This must be started by executing the program SYS$IRDA.IMG (from ROM:: on the 3c) in the normal way (system calls FilExecute and ProcResume).

Function 4 has the side effect of disconnecting from the remote machine if a connection is established.

Function 5

  • Argument 1: application name (cstr)
  • Argument 2: buffer

Waits for a connection from another machine, completing when another machine connects successfully. If the call is successful, the buffer is filled with a cstr containing information from the other machine (up to 56 characters excluding the terminating zero) and the call returns the maximum amount of data that may be sent in a single write.

Function 6

  • Argument 1: information block
  • Argument 2: maximum number of machines to find

Searches the physical neighbourhood for machines willing to accept an IrDA connection. The second argument is overwritten with the actual number of machines found, and 36 bytes are placed in the buffer for each machine:

Offset Length Description
0 4 Unknown
4 4 machine address
8 4 Unknown
12 23 (cstr) machine nickname (up to 23 characters)

Function 7

  • Argument 1: machine address
  • Argument 2: unused

The device is initialised ready to connect to the specified machine.

Function 8

  • Argument 1: application name (cstr)
  • Argument 2: buffer

Connects to the specified application on the selected machine. If the connection is successful, the buffer is filled with the information passed from the other machine (up to 60 bytes). The application name is limited to 25 characters excluding the terminating zero. If this call is successful, it returns the maximum amount of data that can be sent in a single write.

Console device

This is a special device that does not need to be opened; it has the handle -2.

The console device outputs text in the text area (as set by the SCREEN keyword), and many of its functions duplicate OPL keywords. Up to 255 characters may be written to the device, and the corresponding text will be output. Certain characters have the following meaning:

Character Meaning
7 beep
8 backspace
9 go to next tab stop (multiple of 8 characters)
10 go down one line
11 go down one line
12 go down one screen
13 go to start of the line

If the text will not all fit in the current line, what happens depends on the auto-wrap and scroll lock flags (defined below). If auto wrap is on, moving past the end of the line moves to the beginning of the next line. Otherwise further characters overwrite the last character on the line. If scroll lock is off, moving down from the bottom line (including because of an auto wrap) will scroll the screen up one line. Otherwise moving down from the bottom line has no effect. Writing cannot fail.

Reading from the device ignores the length and always reads exactly 4 bytes, representing a single keystroke:

  • Offset 0 (word): keycode
  • Offset 2 (byte): modifiers
    • Bit 1: set if SHIFT pressed
    • Bit 2: set if CONTROL pressed
    • Bit 3: set if PSION pressed
    • Bit 4: set if CAPS LOCK in effect
    • Bit 5: set if NUM LOCK in effect
  • Offset 3 (byte): autorepeat count

The autorepeat count indicates how many keystrokes have been combined into one return; it will only be greater than 1 if processing of the keystrokes is not keeping up with the autorepeat.

Function 7

Argument 1 = 0

  • Argument 1: (word) the value 0
  • Argument 2: (word) style

This alters the text style as specified:

  • Bit 0: bold
  • Bit 1: reverse
  • Bit 2: underline
  • Bit 3: flashing
  • Bit 4: italic

Unsupported styles and those requiring a different character width will be silently ignored. This function cannot fail.

Argument 1 = 1

  • Argument 1: (word) the value 1
  • Argument 2: control block

This scrolls a rectangle (ignoring the scroll lock flag) by any amount according to the control block:

Offset Length Description
0 2 left edge of rectangle (inclusive)
2 2 top edge of rectangle (inclusive)
4 2 right edge of rectangle (exclusive)
6 2 bottom edge of rectangle (exclusive)
8 2 horizontal scroll distance (positive=right, negative=left)
10 2 vertical scroll distance (positive=down, negative=up)

The rectangle will be clipped to the text area. This function cannot fail.

Argument 1 = 2

  • Argument 1: (word) the value 2
  • Argument 2: control block

This clears a rectangular area described by the control block:

Offset Length Description
0 2 left edge of rectangle (inclusive)
2 2 top edge of rectangle (inclusive)
4 2 right edge of rectangle (exclusive)
6 2 bottom edge of rectangle (exclusive)

The rectangle will be clipped to the text area. This function cannot fail.

Argument 1 = 3

  • Argument 1: (word) the value 3
  • Argument 2: control block

The cursor moves to the specified location; if that is outside the text area, it moves to the closest point within. The control block has the format:

Offset Length Description
0 2 x coordinate
2 2 y coordinate

This function cannot fail.

Argument 1 = 4

  • Argument 1: (word) the value 4
  • Argument 2: control block

The cursor moves the specified amount, or to the edge of the text area if that is closer. The control block has the format:

Offset Length Description
0 2 horizontal distance to move (positive=right, negative=left)
2 2 vertical distance to move (positive=down, negative=up)

This function cannot fail.

Argument 1 = 5

  • Argument 1: (word) the value 5
  • Argument 2: control block

Sets the size of the text area according to the control block:

Offset Length Description
0 4 must be zero
4 2 new width
6 2 new height

Argument 1 = 6 or 7

  • Argument 1: (word) the value 6 (for scroll lock) or 7 (for auto wrap)
  • Argument 2: (word) 0 for off or 1 for on

Sets the scroll lock or auto wrap flag. This function cannot fail. The initial state is auto wrap on and scroll lock off.

Argument 1 = 8

  • Argument 1: (word) the value 8
  • Argument 2: unused

Moves the cursor to the start of the next line, obeying the scroll lock flag. This function cannot fail.

Argument 1 = 9

  • Argument 1: (word) the value 9
  • Argument 2: (word) 0 to turn cursor off, 1 to turn it on

Turns the cursor on or off; this has no effect other than altering the appearance of the cursor on the screen. This function cannot fail.

Argument 1 = 10

  • Argument 1: (word) the value 10
  • Argument 2: (word) 0 to disable, 1 to enable (default)

Enables or disables exiting via the PSION-ESC key sequence. This function cannot fail.

Argument 1 = 11

  • Argument 1: (word) the value 11
  • Argument 2: (word) 0 for buffering, 1 for immediate execution (default)

Enables or disables buffering of commands. When buffering is in effect, calls to the console are buffered up, and executed only when the buffer is full, a result is required, or on an explicit flush of the buffer. As a side effect, errors will be reported to the function causing the buffer contents to be executed, not the one making the call. This function cannot fail.

Argument 1 = 12

  • Argument 1: (word) the value 12
  • Argument 2: control block

Sets the text area according to the control block:

Offset Length Description
0 2 left edge (inclusive) of the text area
2 2 top edge (inclusive) of the text area
4 2 right edge (exclusive) of the text area
6 2 bottom edge (exclusive) of the text area

Argument 1 = 13 or 14

  • Argument 1: (word) the value 13 (set up) or 14 (cancel)
  • Argument 2: control block

Sets up or cancels capturing of a key or combination of keys by this process, whether or not it is in the foreground. The cancel must specify an identical control block to the set up. The control block has the format:

Offset Length Description
0 2 keycode
2 1 modifiers that must be pressed (if tested)
3 1 modifiers that are tested

Both modifier values use the bits:

  • Bit 1: set if SHIFT pressed
  • Bit 2: set if CONTROL pressed
  • Bit 3: set if PSION pressed
  • Bit 4: set if CAPS LOCK in effect
  • Bit 5: set if NUM LOCK in effect

Unused bits must be zero, and a bit must not be set in offset 2 while clear in offset 3.

Argument 1 = 15

  • Argument 1: (word) the value 15
  • Argument 2: (word) process id

Moves the indicated process to the foreground. This call cannot fail.

Argument 1 = 16

  • Argument 1: (word) the value 16
  • Argument 2: (word) 0 for off or 1 for on

Sets the last line wrap flag. This function cannot fail. The initial state of the flag is off. When off, printing to the bottom right corner of the text area causes an immediate wrap and scroll. @???@ @Obeys other flags@

Argument 1 = 17

  • Argument 1: (word) the value 17
  • Argument 2: control block

This sets the font type for the text area, resizing the latter as necessary to handle the new font, and clears the text area. The control word has the format:

  • Offset 0 (word): window server font id
  • Offset 2 (word): style
    • Bit 0: bold (by double printing)
    • Bit 1: underlined
    • Bit 2: inverse
    • Bit 3: double height
    • Bit 4: must be set for proportional fonts, ignored for monospaced fonts
    • Bit 5: italic (by printing the top half one pixel to the right)

Note that the console device uses a fixed character grid; if a proportional font is chosen, bit 4 of the style must be selected, and the characters will be printed on that grid, and not proportionally.

Window server font ids are 0x3FFF greater than the OPL font id @CHECK@. The current system font has id 0x4099 (widget server) or 0x9A (OPL).

Argument 1 = 18

  • Argument 1: (word) the value 18
  • Argument 2: (word) 0 for disabled, 1 for enabled (default)

Enables or disables reads from the console. The console may only be read (via functions 1, 14, or the equivalent OPL keywords) when enabled. This function cannot fail.

@@Subs: 19 SET_PRIORITY_CONTROL, 20 COMPATIBILITY, 21 GREY, 22 FONT_EXT ??

Function 8

  • Argument 1: 12 byte buffer
  • Argument 2: must be the same as Argument 1

The position of the text area and the current cursor position (as set by the AT keyword) are written into the buffer.

Offset Length Description
0 2 set to left edge (inclusive) of the text area
2 2 set to top edge (inclusive) of the text area
4 2 set to right edge (exclusive) of the text area
6 2 set to bottom edge (exclusive) of the text area
8 2 set to cursor x coordinate relative to offset 0
10 2 set to cursor y coordinate relative to offset 2

All coordinates are in character positions. 0,0 is the top left corner of the screen; note that the bottom and right edges are outside the text area. This function cannot fail.

Function 9

  • Argument 1: unused
  • Argument 2: unused

This function discards any waiting keypresses. It cannot fail.

Function 10

  • Argument 1: word set to 1 if keypresses waiting, and 0 otherwise
  • Argument 2: unused

This function tests whether there are any keypresses waiting. It cannot fail.

Function 11

  • Argument 1: 258 byte control block
  • Argument 2: word holding maximum length

This function allows the user to edit a string on the screen. The control block has the following format:

Offset Length Description
0 1 unused
1 1 non-zero allows escape from editing
2 256 string buffer

The initial value of the string must be placed in the buffer; the resulting string will also be placed there (in both cases it is a cstr). The length of the string, excluding the terminating zero, is limited to the specified maximum. If ESC is pressed with the string currently non-empty, it is cleared. If ESC is pressed with the string empty and escaping is allowed, the function
will fail; otherwise ESC will be ignored in this circumstance.

Function 12

  • Argument 1: 8 byte buffer
  • Argument 2: unused

The buffer is filled with information about the text area:

Offset Length Description
0 2 window server id of the console window
2 2 window server id of the console font
4 2 height of a text line in pixels
6 2 width of a text character in pixels

This function cannot fail.

Function 13

  • Argument 1: unused
  • Argument 2: unused

If console buffering is in effect, any buffered commands are executed. Otherwise this function has no effect. It cannot fail.

Function 14

  • Argument 1: 4 byte buffer
  • Argument 2: unused

This function is equivalent to the GETEVENT keyword. It behaves the same as reading from the device, except that events other than keypresses can be returned; for example, foreground, background, and change file events. Unlike GETEVENT, this function can be called from OPL programs whether or not they are OPA applications.

Function 15

  • Argument 1: word set to 1 if any events waiting, and 0 otherwise
  • Argument 2: unused

This function is equivalent to the TESTEVENT keyword. It behaves the same as function 10 except that events other than keypresses are also detected. It cannot fail.